WJPPS Citation

Login

Search

News & Updation

  • Journal web site support Internet Explorer, Google Chrome, Mozilla Firefox, Opera, Saffari for easy download of article without any trouble.
  •  
  • Updated Version
  • WJPPS introducing updated version of OSTS (online submission and tracking system), which have dedicated control panel for both author and reviewer. Using this control panel author can submit manuscript
  • Call for Paper
    • WJPPS  Invited to submit your valuable manuscripts for Coming Issue.
  • ICV
  • WJPPS Rank with Index Copernicus Value 84.65 due to high reputation at International Level

  • Scope Indexed
  • WJPPS is indexed in Scope Database based on the recommendation of the Content Selection Committee (CSC).

  • WJPPS: New Impact Factor 2026
  • WJPPS Impact Factor has been Increased to 8.485 for Year 2026.

  • WJPPS: JULY ISSUE PUBLISHED
  • JULY 2026 Issue has been successfully launched on 1 JULY 2026.

Abstract

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR THE SIMULTANEOUS ESTIMATION OF SERDEXMETHYLPHENIDATE AND DEXMETHYLPHENIDATE IN BULK AND PHARMACEUTICAL DOSAGE FORM

Malepati Ramakrishna*, Koduri Nandini, J. N. Suresh Kumar

ABSTRACT

An accurate, precise, simple, efficient and reproducible, isocratic Reversed Phase-High Performance Liquid Chromatography (RP-HPLC) method was developed and validated for the simultaneous estimation of Serdex methyl phenidate and Dexmethylphenidate in bulk and combined pharmaceutical tablet dosage forms. Serdexmethylphenidate and Dexmethylphenidate were separated by using a Symmetry ODS C18 (4.6mm×150mm) 5µm Particle Size; Waters Alliance e2695 HPLC system with 2998 PDA detector and the mobile phase contained a mixture of Methanol: 0.1% Orthophosphoric acid (64:36% v/v). The flow rate was set to 1ml/min with the responses measured at 224nm. The retention time of Serdexmethylphenidate and Dexmethylphenidate was found to be 2.808min and 3.880min respectively with resolution of 5.68. Linearity was established for Serdexmethylphenidate and Dexmethylphenidate in the range of 20-100µg/ml for Serdexmethylphenidate and 60-140µg/ml for Dexmethylphenidate with correlation coefficient 0.999. The percentage recovery was found to be is 100.30% for Serdexmethylphenidate and 100.21% for Dexmethylphenidate respectively. Validation parameters such as specificity, linearity, precision, accuracy and robustness, limit of detection (LOD) and limit of quantitation (LOQ) were evaluated for the method according to the International Conference on Harmonization (ICH) Q2 R1 guidelines. The developed method was successfully applied for the quantification of bulk and active pharmaceutical ingredient present and in combined tablet dosage form.

Keywords: Serdexmethylphenidate and Dexmethylphenidate, RP-HPLC, Validation, Accuracy, Robustness.