WJPPS Citation Report

Submit Article

Search

News & Updation

  • Journal web site support Internet Explorer, Google Chrome, Mozilla Firefox, Opera, Saffari for easy download of article without any trouble.
  •  
  • Updated Version
  • WJPPS introducing updated version of OSTS (online submission and tracking system), which have dedicated control panel for both author and reviewer. Using this control panel author can submit manuscript
  • Call for Paper
    • WJPPS  Invited to submit your valuable manuscripts for Coming Issue.
  • ICV
  • WJPPS Rank with Index Copernicus Value 84.65 due to high reputation at International Level

  • Scope Indexed
  • WJPPS is indexed in Scope Database based on the recommendation of the Content Selection Committee (CSC).

  • WJPPS: New Impact Factor 2026
  • WJPPS Impact Factor has been Increased to 8.485 for Year 2026.

  • WJPPS: NOVEMBER ISSUE PUBLISHED
  • NOVEMBER 2026 Issue has been successfully launched on 1 NOVEMBER 2026.

Abstract

DEVELOPMENT OF ANALYTICAL SPECIFICATIONS AND VALIDATION OF RUTOSIDE TRIHYDRATE USING RP-HPLC

Anil Sharma*, Dr. Pramod Kumar Goyal, Dr. Piush Sharma

ABSTRACT

Background: Rutoside Trihydrate is a flavonoid glycoside with vasoprotective and antioxidant properties. The present study aimed to develop and validate an RP-HPLC method for the quantitative estimation of Rutoside Trihydrate in pharmaceutical formulations. Materials and Methods: Rutoside Trihydrate was analyzed using an RP-HPLC system with a UV detector and C18 column (250 × 4.6 mm, 5 µm). Methanol:water (70:30 v/v) was used as the mobile phase at a flow rate of 1.0 mL/min. The injection volume was 20 µL and detection was carried out at 257 nm. The method was validated for system suitability, specificity, linearity, accuracy, precision, sensitivity, robustness, and forced degradation. Results: Rutoside Trihydrate showed a retention time of 4.26 min, with a theoretical plate count of 4862 and a tailing factor of 1.12.The method showed good linearity over 10–50 µg/mL with a correlation coefficient of 0.9997. The mean recovery was 99.90%. The limit of detection and limit of quantification were 0.0063 and 0.0191 µg/mL, respectively. Forced degradation showed 8.42% degradation under acidic, 11.36% under alkaline, 7.85% under oxidative, 5.26% under thermal, and 6.74% under photolytic conditions. The degradation products were separated from the main drug peak. Conclusion: The developed RP-HPLC method was found to be accurate, precise, sensitive, robust, and stability-indicating. The assay of the pharmaceutical formulation was 99.42% with a %RSD of 0.09%. The method is suitable for routine estimation and quality control of Rutoside Trihydrate in pharmaceutical formulations.

Keywords: Rutoside Trihydrate; Rutin; RP-HPLC; Method Validation; Forced Degradation; Stability-Indicating Method.