ANALYTICAL METHOD DEVELPMENT AND VALIDATION OF ASSAY OF SODIUM PICOSULFATE BY USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY
S. Vikram*, P. D. Gokulan and K. L. Senthil Kumar
ABSTRACT The developed High Performance liquid Chromatography (HPLC) method for the analysis of Development and Validation of Estimation of Assay in Sodium Picosulfate is Precise and feasible. The separation was carried out on the Hypersil C18 Column, (length- 250mm x Inner Diameter-4.6 mm), 5.0 μm; using 28:72 of Ammonium acetate Buffer and Acetonitrile as Mobile Phase, with Flow rate 1.0 mL/min, Column temperature-40oC, Sample temperature-15oC, Wavelength at 210nm, Injection volume is 10 μL, Run time-10 minutes, Diluent-1 is Ethanol and Diluent-2 is Water. Peak shape found satisfactory. System suitability parameter were meets the acceptance criteria and %Relative standard deviation was within the limit. The Correlation coefficient of Linearity for individual solvent, obtained from three replicate injection are not less than 0.998. And all the level of Recoveries are within the limit of 80% to 120%. The method was validated as per International Council for Harmonization (ICH) norms and the method is also costeffective. The proposed method is useful for rapid analysis of estimation of Assay in Sodium Picosulfate. Keywords: High Performance Liquid Chromatography (HPLC), Sodium Picosulfate, UV Detector. [Download Article] [Download Certifiate] |