WJPPS Citation

Login

Search

News & Updation

  • Updated Version
  • WJPPS introducing updated version of OSTS (online submission and tracking system), which have dedicated control panel for both author and reviewer. Using this control panel author can submit manuscript
  • Call for Paper
    • WJPPS  Invited to submit your valuable manuscripts for Coming Issue.
  • Journal web site support Internet Explorer, Google Chrome, Mozilla Firefox, Opera, Saffari for easy download of article without any trouble.
  •  
  • New Impact Factor
  • WJPPS Impact Factor has been Increased to 8.025 for Year 2024.

  • WJPPS: MARCH ISSUE PUBLISHED
  • March Issue has been successfully launched on 1 March 2024.

  • ICV
  • WJPPS Rank with Index Copernicus Value 84.65 due to high reputation at International Level

  • Scope Indexed
  • WJPPS is indexed in Scope Database based on the recommendation of the Content Selection Committee (CSC).

Abstract

IMPACT OF STRESS DISTRIBUTION PATTERN IN FINITE ELEMENT ANALYSIS OF IMPLANT LENGTH, ANGULATION AND ABUTMENT ANGULATION

Abhigyan Manas* and Meenakshi Gupta

ABSTRACT

Objective: Study was to investigate if the use of tilted implants as distal abutments is biomechanically superior to the use of distal cantilevers. Methods: Edentulous 3-D maxillary model was generated from computed tomography images. Four implants were placed in the pre-maxilla and splinted with a titanium bar. Keeping the prosthesis length constant, six different configurations were evaluated with the distal implant varying in length (8 mm, 10 mm, 13 mm); angulation (0, 15, 30, 45°) and abutment angulation (0, 17, 30°). A vertical load (120 N) was applied on the titanium bar corresponding to the position of the left second premolar abutment. Von Mises stress values transmitted to the peri-implant bone and implant abutment junction were evaluated. Results: The maximum stresses recorded at the peri-implant bone and the implant abutment junction were 5.821 MPa and 8.261 MPa for 8 mm vertical implant; 5.358 MPa and 8.131 MPa for the 10 mm implant; and 4.897 MPa and 7.754 MPa for the 13 mm vertical implant. Tilted distal implants resulted in increased stress values for all variables: 8.906 MPa, 8.938 MPa and 8.994 MPa at the peri-implant bone and 14.636 MPa, 15.567 MPa and 16.872 MPa at the implant abutment junction for 15, 30 and 45° respectively. Conclusion: An increase in implant length resulted in a decrease in the stresses, whereas the tilted distal implants and abutments increased the stresses at the peri-implant bone and implant abutment junction of the implants.

Keywords: Study was to investigate if the implants.